Porous titanium alloy/hydroxyapatite composite using powder compaction route

Authors

  • Amir Arifin Department of Mechanical Engineering, Sriwijaya University, 30662 Indralaya, Sumatera Selatan, Indonesia
  • Abu Bakar Sulong Department of Mechanical and Material Engineering, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia
  • Lee Choy Fun Department of Mechanical and Material Engineering, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia
  • Gunawan Department of Mechanical Engineering, Sriwijaya University, 30662 Indralaya, Sumatera Selatan, Indonesia
  • Irsyadi Yani Department of Mechanical Engineering, Sriwijaya University, 30662 Indralaya, Sumatera Selatan, Indonesia

DOI:

https://doi.org/10.15282/jmes.11.2.2017.10.0244%20

Keywords:

titanium-hydroxyapatite foam; space holder method, powder metallurgy.

Abstract

Titanium alloys (Ti6Al4V) and hydroxyapatite (HA) are widely used as implant materials. Ti6Al4V has good mechanical properties and corrosion resistance, whereas HA has excellent biocompatibility but its mechanical properties are weak. The combination of properties between Ti6Al4V and HA is expected to produce a superior material for bio-implants. The aim of this work is to analyse the fabricating porous Ti6Al4V/HA composite through powder compaction with the application of two types of space holders. Sodium chloride (NaCl) and polymethyl methacrylate (PMMA) were selected as the space holder agents. Space holders were removed by solvent debinding (NaCl) and thermal debinding (PMMA). Sintering was performed in a furnace at 1200 °C for 1.5 h. The Archimedes method was carried out to obtain the porosity of the sintered body. Samples where NaCl was used exhibited higher porosity than the samples where for PMMA was used. The high porosity achieved among the successfully sintered samples was 43.9%. Interconnected porous was clearly observed on the sintered composites with a successfully generated size range of 2 μm to 25 μm.

References

Liu J, Ruan J, Chang L, Yang H, Ruan W. Porous nb-ti-ta alloy scaffolds for bone tissue engineering: Fabrication, mechanical properties and in vitro/vivo biocompatibility. Mater Sci Eng C Mater Biol Appl. 2017;78:503-12.

Shirtliff VJ, Hench LL. Bioactive materials for tissue engineering, regeneration and repair. Journal of Materials Science. 2003;38:4697-707.

Mircheski I, Gradisar M. 3d finite element analysis of porous ti-based alloy prostheses. Comput Methods Biomech Biomed Engin. 2016;19:1531-40.

Kanhed S, Awasthi S, Goel S, Pandey A, Sharma R, Upadhyaya A, et al. Porosity distribution affecting mechanical and biological behaviour of hydroxyapatite bioceramic composites. Ceramics International. 2017;43:10442-9.

Kitashima T, Kawamura T. Prediction of oxidation behavior of near-α titanium alloys. Scripta Materialia. 2016;124:56-8.

Meguid SA. Mechanics and mechanisms of toughening of advanced ceramics. Journal of Materials Processing Technology. 1996;56:978-89.

Ravi BG, Chaim R, Gedanken A. Sintering of bimodal alumina powder mixtures with a nanocrystalline component. Nanostructured Materials. 1999;11:853-9.

Cui C, Hu B, Zhao L, Liu S. Titanium alloy production technology, market prospects and industry development. Materials & Design. 2011;32:1684-91.

Niinomi M. Recent research and development in titanium alloys for biomedical applications and healthcare goods. Science and Technology of Advanced Materials. 2003;4:445-54.

Li Y, Munir KS, Lin J, Wen C. Titanium-niobium pentoxide composites for biomedical applications. Bioactive Materials. 2016;1:127-31.

Hamdan SH, Md Said AY, Biki JR. Surface finish when threading titanium-based alloy under dry machining. Journal of Mechanical Engineering and Sciences. 2014;7:1062-9.

Leyens C, Peters M. Titanium and titanium alloys: John Wiley & Sons; 2006.

Zysset PK, Edward Guo X, Edward Hoffler C, Moore KE, Goldstein SA. Elastic modulus and hardness of cortical and trabecular bone lamellae measured by nanoindentation in the human femur. Journal of Biomechanics. 1999;32:1005-12.

Arifin A, Sulong AB, Muhamad N, Syarif J, Ramli MI. Material processing of hydroxyapatite and titanium alloy (ha/ti) composite as implant materials using powder metallurgy: A review. Materials & Design. 2014;55:165-75.

Sopyan I, Gunawan, Shah QH, Mel M. Fabrication and sintering behavior of zinc-doped biphasic calcium phosphate bioceramics. Materials and Manufacturing Processes. 2015;31:713-8.

Ryan G, Pandit A, Apatsidis DP. Fabrication methods of porous metals for use in orthopaedic applications. Biomaterials. 2006;27:2651-70.

Vasconcellos LM, Leite DO, Nascimento FO, Vasconcellos LG, Graca ML, Carvalho YR, et al. Porous titanium for biomedical applications: An experimental study on rabbits. Medicina Oral Patologia Oral Y Cirugia Bucal. 2010:e407-e12.

von Doernberg M-C, von Rechenberg B, Bohner M, Grünenfelder S, van Lenthe GH, Müller R, et al. In vivo behavior of calcium phosphate scaffolds with four different pore sizes. Biomaterials. 2006;27:5186-98.

Chang B-S, Lee iCKfC-K, Hong K-S, Youn H-J, Ryu H-S, Chung S-S, et al. Osteoconduction at porous hydroxyapatite with various pore configurations. Biomaterials. 2000;21:1291-8.

Maleque MA, Radhi M, Rahman MM. Wear study of mg-sicp reinforcement aluminium metal matrix composite. Journal of Mechanical Engineering and Sciences. 2016;10:1758-64.

Fajrin J, Zhuge Y, Bullen F, Wang H. Flexural behaviour of hybrid sandwich panel with natural fiber composites as the intermediate layer. Journal of Mechanical Engineering and Sciences. 2016;10:1968-83.

Yusuf MYM, Selamat MZ, Sahari J, Daud MAM, Tahir MM, Hamdan HA. Fabrication of a flow channel for the production of polymer composite bipolar plates through hot compression molding. Journal of Mechanical Engineering and Sciences. 2017;14:2428-42.

Khan MM, Dixit G. Erosive wear response of sicp reinforced aluminium based metal matrix composite: Effects of test environments. Journal of Mechanical Engineering and Sciences. 2017;14:2401-14.

Haris A, Tay TE, Tan VBC. Experimental analysis of composite bolted joints using digital image correlation. Journal of Mechanical Engineering and Sciences. 2017;14:2443-55.

Kolawole MY, Aweda JO, Abdulkareem S. Archachatina marginata bio-shells as reinforcement material in metal matrix composites. International Journal of Automotive and Mechanical Engineering. 2017;14:4068-79.

Ahmed S, Ahsan A, Hasan M. Physico-mechanical properties of coir and jute fibre reinforced hybrid polyethylene composites. International Journal of Automotive and Mechanical Engineering. 2017;14:3927-37.

Jurczyk M, Jurczyk K, Niespodziana K. The manufacturing of titanium-hydroxyapatite nanocomposites for bone implant applications. Nanopages. 2006;1:219-29.

Zhuravleva K, Chivu A, Teresiak A, Scudino S, Calin M, Schultz L, et al. Porous low modulus ti40nb compacts with electrodeposited hydroxyapatite coating for biomedical applications. Materials Science & Engineering C-Materials for Biological Applications. 2013;33:2280-7.

Niespodziana K, Jurczyk K, Jakubowicz J, Jurczyk M. Fabrication and properties of titanium–hydroxyapatite nanocomposites. Materials Chemistry and Physics. 2010;123:160-5.

Nomura N, Sakamoto K, Takahashi K, Kato S, Abe Y, Doi H, et al. Fabrication and mechanical properties of porous ti/ha composites for bone fixation devices. Materials Transactions. 2010;51:1449-54.

Torres Y, Pavón JJ, Rodríguez JA. Processing and characterization of porous titanium for implants by using nacl as space holder. Journal of Materials Processing Technology. 2012;212:1061-9.

Baklouti S, Bouaziz J, Chartier T, Baumard JF. Binder burnout and evolution of the mechanical strength of dry-pressed ceramics containing poly(vinyl alcohol). Journal of the European Ceramic Society. 2001;21:1087-92.

Belgacem M, Thierry B, Jean-Claude G. Investigations on thermal debinding process for fine 316l stainless steel feedstocks and identification of kinetic parameters from coupling experiments and finite element simulations. Powder Technology. 2013;235:192-202.

Khoong LE, Lam YC, Chai JC, Ma J, Jiang L. Modeling of mass transfers in a porous green compact with two-component binder during thermal debinding. Chemical Engineering Science. 2009;64:2837-50.

Shengjie Y, Lam YC, Chai JC, Tam KC. Simulation of thermal debinding: Effects of mass transport on equivalent stress. Computational Materials Science. 2004;30:496-503.

Mansourighasri A, Muhamad N, Sulong AB. Processing titanium foams using tapioca starch as a space holder. Journal of Materials Processing Technology. 2012;212:83-9.

Torres Y, Pavon JJ, Rodriguez JA. Processing and characterization of porous titanium for implants by using nacl as space holder. Journal of Materials Processing Technology. 2012;212:1061-9.

Shahzeydi MH, Parvanian AM, Panjepour M. The distribution and mechanism of pore formation in copper foams fabricated by lost carbonate sintering method. Materials characterization. 2016;111:21-30.

Lu JX, Flautre B, Anselme K, Hardouin P, Gallur A, Descamps M, et al. Role of interconnections in porous bioceramics on bone recolonization in vitro and in vivo. Journal of Materials Science: Materials in Medicine. 1999;10:111-20.

Ye H, Liu XY, Hong H. Characterization of sintered titanium/hydroxyapatite biocomposite using ftir spectroscopy. J Mater Sci Mater Med. 2009;20:843-50.

Yang Y, Kim K-H, Agrawal CM, Ong JL. Interaction of hydroxyapatite–titanium at elevated temperature in vacuum environment. Biomaterials. 2004;25:2927-32.

Egorov A, Smirnov V, Shvorneva L, Kutsev S, Barinov S. High-temperature hydroxyapatite-titanium interaction. Inorganic Materials. 2010;46:168-71.

Berezhnaya A, Mittova V, Kostyuchenko A, Mittova I. Solid-phase interaction in the hydroxyapatite/titanium heterostructures upon high-temperature annealing in air and argon. Inorganic Materials. 2008;44:1214-7.

Gunawan, Sopyan I, Nurfaezah S, ‘Ammar M. Development of triphasic calcium phosphate–carbon nanotubes (ha/tcp-cnt) composite: A preliminary study. Key Engineering Materials. 2012;531-532:258-61.

Salman S, Gunduz O, Yilmaz S, Öveçoğlu ML, Snyder RL, Agathopoulos S, et al. Sintering effect on mechanical properties of composites of natural hydroxyapatites and titanium. Ceramics International 2009;35:2965-71.

Tõnsuaadu K, Gross KA, Plūduma L, Veiderma M. A review on the thermal stability of calcium apatites. Journal of Thermal Analysis and Calorimetry. 2011;110:647-59.

Downloads

Published

2017-06-30

How to Cite

[1]
Amir Arifin, Abu Bakar Sulong, Lee Choy Fun, Gunawan, and Irsyadi Yani, “Porous titanium alloy/hydroxyapatite composite using powder compaction route”, J. Mech. Eng. Sci., vol. 11, no. 2, pp. 2679–2692, Jun. 2017.

Issue

Section

Article

Similar Articles

<< < 23 24 25 26 27 28 29 > >> 

You may also start an advanced similarity search for this article.