Capability of pipe inside an actuator to move in various fluid and oil surfaces

Authors

  • Hiroyuki Yaguchi Faculty of Mechanical Engineering, Tohoku Gakuin University, 1-13-1 Chuo, Tagajo, Miyagi, Japan
  • Keito Murai Faculty of Mechanical Engineering, Tohoku Gakuin University, 1-13-1 Chuo, Tagajo, Miyagi, Japan
  • Keita Yaegashi Faculty of Mechanical Engineering, Tohoku Gakuin University, 1-13-1 Chuo, Tagajo, Miyagi, Japan

DOI:

https://doi.org/10.15282/jmes.11.3.2017.11.0262

Keywords:

magnetic actuator, pipe inside mover, supporting force, frictional force, shape memory alloy.

Abstract

This paper proposes a novel pipe inside a magnetic actuator that operates on the elastic energy of a vibration component excited by electromagnetic force. Flexible material such as rubber was used to support the actuator in the pipe and was used as a means of transferring elastic energy. The actuator is moved by the difference between forward and backward forces of support point of actuator. In the experiment, the actuator that was shielded by a thin acrylic hollow cylinder for movement inside a pipe with an inner diameter of 11 mm was prototyped. Characteristics of movement for the actuator were measured in air and water. The actuator could climb at 14.1 mm/s when pulling a load mass of 30 g. In the water, the speed of the actuator compared to the air was approximately 50 % by viscosity resistance of the water. In addition, a prototype of a new magnetic actuator combined with a memory alloy (SMA) wire and an electromagnetic vibration component was proposed and fabricated. In the actuator, the supporting force inside the pipe can be varied by the SMA wire. The speed of the actuator was measured in a pipe soiled with oil. In a pipe with a coefficient of friction of 0.28, it can pull vertically at a speed of 2 mm/s while generating a traction force of 0.088 N. Experimental results demonstrated that this actuator can be used in various environments such as atmospheric air, underwater, and piping with corroded parts. In the future, it is possible to observe the damaged condition inside the piping by mounting a micro CCD-camera on the actuator.

References

Li Y, Cheng T, Xuan D, Shen Y. Force characteristic of a magnetic actuator for separable electric connector based on conical airgap. Advances in Mechanical Engineering. 2015;7:168781401556894.

Nagai S, Nozaki T, Kawamura A. Real-time Sensorless Estimation of Position and Force for Solenoid Actuators. IEEJ Journal of Industry Applications. 2016;5:32-8.

Kelemenová T, Frankovský P, Virgala I, Miková Ľ, Kelemen M. Machines for inspection of pipes. Acta Mechatronica. 2016;1:1-7.

Virgala I, Gmiterko A, Kelemen M. Motion analysis of in-pipe robot based on SMA spring actuator. Journal of Automation and Control. 2013;1:21-5.

Kim J, Kim MJ, Yoo J, Kim S-J. Novel Motion Modes for 2-D Locomotion of a Microrobot. IEEE Transactions on Magnetics. 2014;50:1-5.

Choi K, Jang G, Jeon S, Nam J. Capsule-Type Magnetic Microrobot Actuated by an External Magnetic Field for Selective Drug Delivery in Human Blood Vessels. IEEE Transactions on Magnetics. 2014;50:1-4.

Kim SH, Shin JW, Ishiyama K. Multiscale Magnetic Spiral-Type Machines for Fluid Manipulation. IEEE Transactions on Magnetics. 2014;50:1-4.

Guo J, Guo S, Wei X, Gao Q. A Novel tele-operation controller for wireless microrobots in-pipe with hybrid motion. Robotics and Autonomous Systems. 2016;76:68-79.

Shukla A, Karki H. Application of robotics in onshore oil and gas industry—A review Part I. Robotics and Autonomous Systems. 2016;75:490-507.

Guo J, Guo S, Wei X, Wang Y. Development of Wireless Endoscope with Symmetrical Motion Characteristics. International Journal of Advanced Robotic Systems. 2014;11:148.

Yaguchi H, Sato N. Globular Magnetic Actuator Capable of Free Movement in a Complex Pipe. IEEE Transactions on Magnetics. 2010;46:1350-5.

Yaguchi H, Kamata K. In-piping Magnetic Actuator Capable of Inspection in a Thin Complex Pipe. Mechanical Engineering Research. 2012;2.

Yaguchi H. Magnetic Actuator Capable of Inspection in a Complex Pipe by Phase Control of Multiple Electromagnetic Vibration Components. IEEE Transactions on Magnetics. 2015;51:1-4.

Yaguchi H, Sato N, Shikoda A. Magnetic Actuator Group of Globular Type Capable of Free Movement in a Complex Pipe. IEEE Transactions on Magnetics. 2011;47:4159-62.

Yaguchi H, Sasaki K. New type of magnetic actuator system for inspection in a complex pipe. IEEE Transactions on Magnetics. 2013;49:3905-8.

Lee J-Y. Sound and Vibration Signal Analysis using Improved Short-Time Fourier Representation. International Journal of Automotive and Mechanical Engineering. 2013;7:811-9.

Hassan MZ, Magaswaran K, Phuman Singh AS. A new method in the identification of noise and vibration characteristics of automotive disk brakes in the low frequency domain. International Journal of Automotive and Mechanical Engineering (IJAME). 2014;9:1554-77.

Patel CB, Gohil PP, Borhade B. Modeling and Vibration Analysis of Road Profile Measuring System. International Journal of Automotive and Mechanical Engineering. 2010;1:13-28.

Martynenko G. Resonance mode detuning in rotor systems employing active and passive magnetic bearings with controlled stiffness. International Journal of Automotive and Mechanical Engineering. 2016;13:3293-308.

Kachare PS, Bimleshkumar. Effect of Particle size and packing ratio of PID on vibration amplitude of beam. Journal of Mechanical Engineering and Sciences. 2013;4:504-17.

Khair FA, Putra A, Nor MJ, Selamat MZ. Analysis of sound absorption of hollow tube absorbers. International Journal of Automotive and Mechanical Engineering. 2016;13:3492.

Kob MSC, Supriyo B, Tawi KB, Mazali II. Engagement slip controller development based on actuator displacement for an electro-mechanical friction clutch system. International Journal of Automotive and Mechanical Engineering. 2015;11:2664.

Downloads

Published

2017-09-30

How to Cite

[1]
Hiroyuki Yaguchi, Keito Murai, and Keita Yaegashi, “Capability of pipe inside an actuator to move in various fluid and oil surfaces”, J. Mech. Eng. Sci., vol. 11, no. 3, pp. 2906–2918, Sep. 2017.