Dynamic Fatigue Behavior of Hip Joint under Patient Specific Loadings

Authors

  • Tanuj Joshi Department of Mechanical Engineering, Amity University Haryana, 122413, India
  • Ravikant Sharma Department of Mechanical Engineering, Amity University Haryana, 122413, India
  • Vinod Kumar Mittal Department of Mechanical Engineering, NIT Kurukshetra, 136119, India
  • Vikas Gupta Department of Mechanical Engineering, CDLSIET Panniwala Mota, 125077, India
  • Gopal Krishan School of Innovation, Design and Technology, Wellington Institute of Technology, Wellington, New Zealand

DOI:

https://doi.org/10.15282/ijame.19.3.2022.13.0773

Keywords:

Gait cycle, Fatigue life, Dynamic loading, Abductor muscle , Charnley

Abstract

In the present work, a finite element model with standard Charnley’s implant of hip joint is considered for investigation under different patient-specific dynamic activities obtained in vivo. The application of forces occurred due to human movement, which ultimately generates dynamic stress over the prosthesis. Anatomical loading constraints are more clinically relevant than ISO standards. The performance of different materials for each suitable gait pattern is analyzed using commercial finite element code. A liner isotropic material Ti-6Al-4V and PMMA material is utilized for an implant and bone cement, respectively. However, cortical and cancellous bone are treated as non-isotropic in nature. Clinically obtained dynamic forces and torque are being used for the present investigation. Additionally, Goodman, Solderberg, Gerber and ASME elliptic fatigue theories were considered to obtain the fatigue life of the implant. The most strenuous activity in terms of stress and strain are, going downstairs followed by going upstairs, walking, standing up and sitting down, which have been found in good agreement with the safety factor for every activity. Additionally, the life expectancy of the implant was a minimum of 23 years under every dynamic motion. The present work exhibits the greater relevance in terms of the life expectancy of implant for the pre-surgical analysis before implanted in vivo.

Author Biographies

Ravikant Sharma, Department of Mechanical Engineering, Amity University Haryana, 122413, India

Department of Mechanical Engineering, Assistant Professor

Vinod Kumar Mittal, Department of Mechanical Engineering, NIT Kurukshetra, 136119, India

Department of Mechanical Engineering, Professor

Vikas Gupta, Department of Mechanical Engineering, CDLSIET Panniwala Mota, 125077, India

Department of Mechanical Engineering, Associate Professor and Head

Gopal Krishan, School of Innovation, Design and Technology, Wellington Institute of Technology, Wellington, New Zealand

School of Innovation, Design and Technology, Assistant Professor 

Downloads

Published

2022-10-28

How to Cite

[1]
T. Joshi, R. Sharma, V. K. Mittal, V. . Gupta, and G. Krishan, “Dynamic Fatigue Behavior of Hip Joint under Patient Specific Loadings”, Int. J. Automot. Mech. Eng., vol. 19, no. 3, pp. 10014–10027, Oct. 2022.

Issue

Section

Articles

Similar Articles

<< < 11 12 13 14 15 16 17 18 19 20 > >> 