Thermal performance of a vertical closed loop pulsating heat pipe and analysis using dimensionless numbers

Authors

  • G.V. Pradeep Jain University, Bangalore, Karnataka, 562112, India
  • K. Rama Narasimha K.S. Institute of Technology, Bangalore, Karnataka, 560062, India

DOI:

https://doi.org/10.15282/jmes.11.4.2017.26.0292

Keywords:

Vertical closed loop pulsating heat pipe; dimensionless numbers; working fluids; thermal performance

Abstract

This paper deals with the investigations on the thermal performance of a vertically oriented closed loop pulsating heat pipe (VCLPHP), both experimentally and by the use of dimensionless numbers. The working fluids used are acetone, ethanol, methanol and heptane. The VCLPHP consists of copper capillary tubes bent into five turns. The tube’s inner and outer diameters are 2 mm and 3 mm, respectively, and are made of copper. The lengths of the evaporator, adiabatic and condenser sections are 50 mm, 90 mm and 70 mm, respectively. A constant fill ratio and a constant heat input of 60% and 80W, respectively, were used for the experimental investigations. The evaporator section was heated by means of a strip heater with a heating capacity of 400W. The condenser was cooled by circulating water. The experimental results showed that acetone is a better performer as compared to other fluids in terms of low thermal resistance and high heat transfer coefficient. Heptane showed the lowest thermal performance among all fluids. Ethanol and methanol showed average performance. The dimensional analysis was carried out using Kutateladze number, Prandtl number, Karman number, Bond number and Jacob number. Ethanol which showed an average performance in experimental investigations displayed the best thermal performance in terms of Prandtl number. With respect to Bond number, Karman number and Jacob number, acetone showed the best thermal performance. Heptane showed average thermal performance for all dimensionless numbers. Since the thermal performance of acetone both experimentally and by dimensional analysis was better than other working fluids, it may be considered as a suitable working fluid for application in PHP.

References

Anandan SS, Ramalingam V. Thermal management of electronics: A review of literature. Thermal Science. 2008;12:5-26.

Frijns AJ, Eummelen EH, Nedea SV, Nicole CC, Van Steenhoven AA. Microchannel cooling: simulations and experiments. Turbulence: International Journal. 2004;10:67-74.

Mohammadi N, Mohammadi M, Shafii MB. A review of nanofluidic pulsating heat pipes: suitable choices for thermal management of electronics. Frontiers in Heat Pipes. 2013;3:1-17.

Faghri A. Heat pipes: review, opportunities and challenges. Frontiers in Heat Pipes. 2014;5:1-48.

Akachi H. Structure of a heat pipe. USA, Patent 4921041. 1990.

Karimi G, Culham J. Review and assessment of pulsating heat pipe mechanism for high heat flux electronic cooling. IEEE Ninth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems. 2004;52-9.

Meena P, Rittidech S, Poomsa-Ad N. Application of closed-loop oscillating heat-pipe with check valves (CLOHP/CV) air-preheater for reduced relative-humidity in drying systems. Applied Energy. 2007;84:553-64.

Khandekar S, Gupta A. Embedded pulsating heat pipe radiators. Proceedings of the 14th International Heat Pipe Conference, Florianopolis, Brazil.2007;22-7.

Meena P, Rittidech S. Waste Heat Recovery by Closed-Loop Oscillating Heat Pipe with Check Valve from Pottery Kilns for Energy Thrift. American Journal of Engineering and Applied Sciences. 2008;1:126-30.

Yeunyongkul P, Sakulchangsatjatai P, Kammuang-lue N, Terdtoon P. Experimental investigation of the closed loop oscillating heat pipe condenser for vapor compression refrigeration. Journal of Applied Science and Engineering. 2012;15(2):117-22.

Clement J, Wang X. Design and testing of an oscillating heat pipe for fuel cell cooling applications. Proceedings of the ASME International Mechanical Engineering Congress & Exposition, Denver, Colorado, USA, 2011.

Patel CD, Selokar G, Paul A. Pulsating Heat Pipe Based Heat Exchanger. International Journal of Engineering Research and Science & Technology. 2012;1:12-8.

Ha SJ, Kim JS, Lee SI, Jeong BH. The study of evacuated solar collector using pulsating heat pipe. Frontiers in Heat Pipes. 2012;3:1-5.

Khandekar S, Groll M, Luckchoura V. An introduction to pulsating heat pipes. Electronics Cooling. 2003;9:38-42.

Zhang Y, Faghri A. Advances and unsolved issues in pulsating heat pipes. Heat Transfer Engineering. 2008;29:20-44.

Yang H, Khandekar S, Groll M. Operational limit of closed loop pulsating heat pipes. Applied Thermal Engineering. 2008;28:49-59.

Shafii MB, Faghri A, Zhang Y. Thermal modeling of unlooped and looped pulsating heat pipes. Journal of Heat Transfer. 2001;123:1159-72.

Khandekar S, Groll M. On the definition of pulsating heat pipes: an overview. Proceedings of the Fifth Minsk International Seminar; 2003.

Khandekar S, Panigrahi P, Lefèvre F, Bonjour J. Local hydrodynamics of flow in a pulsating heat pipe: A review. Frontiers in Heat Pipes. 2010;1:1-10.

Riehl RR. Characteristics of an open loop pulsating heat pipe. SAE Technical Paper; 2004.

Pachghare P, Mahalle A. Thermal performance of closed loop pulsating heat pipe using pure and binary working fluids. Frontiers in Heat Pipes. 2012;3:1-6.

Tang X, Sha L, Zhang H, Ju Y. A review of recent experimental investigations and theoretical analyses for pulsating heat pipes. Frontiers in Energy. 2013;7:161-73.

Pachghare P, Mahalle M, Khedkar S. Effect of Working Fluid on Thermal Performance of Closed Loop Pulsating Heat Pipe: A Review. International Journal of Computer Applications. 2012;9:27-31.

Meena P, Rittidech S, Tammasaeng P. Effect of inner diameter and inclination angles on operation limit of closed-loop oscillating heat-pipes with check valves. American Journal of Engineering and Applied Sciences. 2008;1(2):100-3.

Charoensawan P, Khandekar S, Groll M, Terdtoon P. Closed loop pulsating heat pipes: Part A: parametric experimental investigations. Applied Thermal Engineering. 2003;23:2009-20.

Rama Narasimha K, Sridhara S, Rajagopal M, Seetharamu K. Influence of heat input, working fluid and evacuation level on the performance of pulsating heat pipe. Journal of Applied Fluid Mechanics. 2012;5(2): 33-42.

Rama Narasimha K, Varadarajan V, Pundarika G, Narasimha KR. Experimental investigation and performance evaluation of a closed loop pulsating heat pipe. Journal of Applied Fluid Mechanics. 2013;6(2): 267-75.

Zhang X. Experimental study of a pulsating heat pipe using FC-72, ethanol, and water as working fluids. Experimental Heat Transfer. 2004;17:47-67.

Halimi M, Nejad AA, Norouzi M. A Comprehensive experimental investigation of the performance of closed-loop pulsating heat pipes. Journal of Heat Transfer. 2017;139:092003.

Kammuang-lue N, On-ai K, Sakulchangsatjatai P, Terdtoon P. Correlation to predict thermal performance according to working fluids of vertical closed-loop pulsating heat pipe. International Journal of Mechanical, Aerospace, Industrial and Mechatronics Engineering. 2014;8(5):954-62.

Kammuang-lue N, Sakulchangsatjatai P, Terdtoon P. Effect of working fluids on thermal characteristic of a closed-loop pulsating heat pipe heat exchanger: A case of three heat dissipating devices. IEEE Electronics Packaging Technology Conference. 2012;142-7.

Khandekar S, Charoensawan P, Groll M, Terdtoon P. Closed loop pulsating heat pipes Part B: visualization and semi-empirical modeling. Applied Thermal Engineering. 2003;23:2021-33.

Rittidech S, Terdtoon P, Murakami M, Kamonpet P, Jompakdee W. Correlation to predict heat transfer characteristics of a closed-end oscillating heat pipe at normal operating condition. Applied Thermal Engineering. 2003;23:497-510.

Charoensawan P, Terdtoon P. Nondimensional Correlation to predict the thermal performance of a horizontal closed-loop pulsating heat pipe. Proc 14th International Heat Pipe Conference. 2007;22-7.

Kline SJ. Describing uncertainty in single-sample experiments. Mechanical Engineering. 1953;75:3-8.

Katpradit T, Wongratanaphisan T, Terdtoon P, Kamonpet P, Polchai A, Akbarzadeh A. Correlation to predict heat transfer characteristics of a closed end oscillating heat pipe at critical state. Applied Thermal Engineering. 2005;25:2138-51.

Taft B, Drolen B, Williams A. Working fluid selection for pulsating heat pipes. 42nd AIAA Thermophysics Conference. 2011;3763.

Khandekar S, Schneider M, Schafer P, Kulenovic R, Groll M. Thermofluid dynamic study of flat-plate closed-loop pulsating heat pipes. Microscale thermophysical engineering. 2002;6:303-17.

Khandekar S. Thermo-hydrodynamics of closed loop pulsating heat pipes. 2004.

Rama Narasimha K. Studies on pulsating heat pipes. India: Visvesvaraya Technological University; 2010.

Downloads

Published

2017-12-31

How to Cite

[1]
G. Pradeep and K. Rama Narasimha, “Thermal performance of a vertical closed loop pulsating heat pipe and analysis using dimensionless numbers”, J. Mech. Eng. Sci., vol. 11, no. 4, pp. 3240–3255, Dec. 2017.

Similar Articles

<< < 4 5 6 7 8 9 10 11 12 13 > >> 

You may also start an advanced similarity search for this article.