An experimental investigation on the performance of a thermoelectric dehumidification system

Authors

  • P. Rakkwamsuk Materials Technology Division, School of Energy, Environment  and  Materials, King Mongkut’s University of Technology Thonburi, 126 Pracha Uthit Rd., Bang Mod, Thung Khru, Bangkok 10140, Thailand
  • P. Paromupatham Energy Technology Division, School of Energy, Environment  and  Materials, King Mongkut’s University of Technology Thonburi, 126 Pracha Uthit Rd., Bang Mod, Thung Khru, Bangkok 10140, Thailand
  • K. Sathapornprasath Department of Mechanical Engineering, Faculty of Engineering, Srinakharinwirot University, 63, Moo 7, Ongkharak, Nakorn Nayok, 26120, Thailand
  • C. Lertsatitthanakorn Energy Technology Division, School of Energy, Environment  and  Materials, King Mongkut’s University of Technology Thonburi, 126 Pracha Uthit Rd., Bang Mod, Thung Khru, Bangkok 10140, Thailand
  • S. Soponronnarit Energy Technology Division, School of Energy, Environment  and  Materials, King Mongkut’s University of Technology Thonburi, 126 Pracha Uthit Rd., Bang Mod, Thung Khru, Bangkok 10140, Thailand

DOI:

https://doi.org/10.15282/jmes.12.4.2018.10.0356

Keywords:

Thermoelectric, COP, Heat sink

Abstract

A thermoelectric (TE) air-cooling system for dehumidifying indoor air in a building was investigated. The system was composed of 4 TE modules. The cold sides of the TE modules were fixed to an aluminum heat sink to remove moisture in the air of a test chamber of 1 m3 volume, while a heat sink with circulating cooling water at the hot sides of the TE modules was used for heat release. The effects of input electric current to the TE modules and air flow rate through the heat sink were experimentally determined. The system’s performance was evaluated using dehumidification effectiveness and coefficient of performance (COP). A suitable condition occurred at 18.5 A of current flow and 240 W of power being supplied to the TE modules with a corresponding cooling capacity of 149.5 W, which gave a dehumidification effectiveness of 0.62. Therefore, it is anticipated the proposed TE dehumidifier concept will contribute to the air conditioning system’s reduction of room humidity. 

References

Atthajariyakul S, Lertsatitthanakorn C. Small fan assisted air conditioner for thermal comfort and energy saving in Thailand. Energy Conversion and Management. 2008; 49:2499-504.

Zafirah MF, Mardiana A. Experimental investigation on the performance of an air-to-air energy recovery for building applications in hot-humid climate. Journal

of Mechanical Engineering and Sciences. 2016; 10:1857-64.

Bassuoni MM. An experimental study of structured packing dehumidifier/ regenerator operating with liquid desiccant. Energy. 2011; 36:2528-38.

Lertsatitthanakorn C, Wiset L, Atthanjariyakul S. Evaluating of thermal comfort of thermoelectric ceiling cooling panel (TE-CCP) system. Journal of Electronic Materials. 2009; 38:1472-77.

Rahbar N, Esfahani JA. Experimental study of a novel portable solar still by utilizing the heatpipe and thermoelectric module. Desalination. 2012; 284:55-61.

Yildirim C, Soylu SK, Armaca I, Solmus I. Experimental investigation of a portable desalination unit configured by a thermoelectric cooler. Energy Conversion and Management. 2014; 85:140-5.

Dehghan AA, Afshari A, Rahbar N. Thermal modeling and exergetic analysis of a thermoelectric assisted solar still. Solar Energy. 2015; 115:277-88.

Irshad K, Habib K, Thirumalaiswamy N, Saha BB. Performance analysis of thermoelectric air duct system for energy-efficient buildings. Energy. 2015; 91:1009-17.

Irshad K, Habib K, Basrawi F, Thirumalaiswamy N, Saidur R, Saha BB.Thermal

comfort study of a building equipped with thermoelectric air duct system for tropical climate. Applied Thermal Engineering. 2015; 91:1141-55.

Riffat RB, Ma X. Improving the coefficienct of performance of thermoelectric cooling systems: a review. International Journal of Energy Research. 2004; 28:753-68.

Sangmesh B, Gopalakrishna K, Manjunath SH, Kathyayini N, Kadirgana K, Samykano M, Vijayakumar GC. Experimental investigation on HSFP using MWCNT based nanofluids for high power light emitting diodes. Journal of Mechanical Engineering and Sciences. 2018; 12:3852-65.

Rahbar N, Gharaiian A, Rashidi S. Exergy and economic analysis for a double slope solar still equipped by thermoelectric heating modules – an experimental investigation. Desalination. 2017; 420: 106-13.

David B, Ramousse J, Luo L. Optimization of thermoelectric heat pump by operating condition management and heat exchanger design. Energy Conversion and Management. 2012; 60:125-33.

Arora CP. Refrigeration and Air Conditioning. 2nd ed. New Delhi: Tata McGraw-Hill; 2001.

Al-Madhhachi H, Min G. Ker factors affecting the production in a thermoelectric distillation system. Energy Conversion and Management. 2018; 165:459-64.

Khedari J, Yamtripat N, Pratintong N, Hirunlabh J. Thailand ventilation comfort chart. Energy and Buildings. 2000; 32:245-49.

Downloads

Published

2018-12-27

How to Cite

[1]
P. Rakkwamsuk, P. Paromupatham, K. Sathapornprasath, C. Lertsatitthanakorn, and S. Soponronnarit, “An experimental investigation on the performance of a thermoelectric dehumidification system”, J. Mech. Eng. Sci., vol. 12, no. 4, pp. 4117–4126, Dec. 2018.

Similar Articles

<< < 4 5 6 7 8 9 10 11 12 13 > >> 

You may also start an advanced similarity search for this article.