Sound Transmission Loss of A Double-Leaf Partition with Micro-Perforated Plate Insertion under Diffuse Field Incidence

Authors

  • A. Putra, A. Y. Ismail, Md. R. Ayob

DOI:

https://doi.org/10.15282/ijame.7.2012.23.0088

Keywords:

Transmission loss; double-panel; noise; MPP; acoustics

Abstract

In noise control applications, a double-leaf partition has been applied widely as a lightweight structure for noise insulation, such as in car doors, train bodies, and aircraft-mass resonance due to coupling between the panels and the air in the gap. This paper investigates the effect of a micro-perforated panel (MPP), inserted in the conventional double-panel partition, on sound transmission loss at troublesome resonant frequencies. It is found that the transmission loss improves at this resonance if the MPP is located at a distance of less than half that of the air gap. A mathematical model is derived for the diffuse field incidence of acoustic loading.

Downloads

Published

2022-12-09

How to Cite

[1]
A. Putra, A. Y. Ismail, Md. R. Ayob, “Sound Transmission Loss of A Double-Leaf Partition with Micro-Perforated Plate Insertion under Diffuse Field Incidence”, Int. J. Automot. Mech. Eng., vol. 7, pp. 1086–1095, Dec. 2022.