Energy and Exergy Investigation of a Solar Air Heater for Different Absorber Plate Configurations

Authors

  • Mustafa J Al-Dulaimi Department of Air Conditioning, Al Esraa University College, 10069, Baghdad, Iraq
  • Areej H. Hilal Department of Air Conditioning, Al Esraa University College, 10069, Baghdad, Iraq
  • Husam A. Hassan Department of Studies, Planning & Follow-up, Ministry of Higher Education & Scientific Research,10060 Baghdad, Iraq
  • Faik A. Hamad School of Science & Engineering, Teesside University, Middlesbrough, TS1 3BA, UK

DOI:

https://doi.org/10.15282/ijame.20.1.2023.08.0793

Keywords:

Double pass solar air heater;, Thermal performance;, Flat Solar air heater;, Thermal efficiency;, Finned surface

Abstract

In this paper, the effect of using different configurations of absorber plate, including one line finned flat absorber and two lines finned absorber plate, on the thermal performance of a flat plate – double passing solar air heater was investigated experimentally. L- shape fins are soldered on the absorber plate to roughen the absorber plate and generate vortices to enhance the heat transfer between the working fluid (air) and absorber plate to improve the thermal efficiency. The outdoor experimental test was carried out during February and May under the weather conditions of Baghdad city (Longitude 33.3 N and Latitude 44.44 E). The results show that the air temperature is 48 ℃, 47.5 ℃, and 58.5 ℃ at an air velocity of 1.7 m/s for a single line of fins which increased to 52 ℃, 57.5 ℃, and 66 ℃ at air velocity of 0.9 m/s for two lines of fins. The efficiency is increased by 28% for one line of fins and 66% for two lines of fins at an air velocity of 0.9 m/s while increased by 27% for one line of fins and 51% for two lines of fins at an air velocity of 1.7 m/s. The average exergy destruction rate increases by 37.6%, 60.6%, and 68.66% for the absorber plate, working fluid, and glass cover, respectively, for velocity increase from 0.9 m/s to 1.9 m/s. The exergy efficiency increased by 24.1% when the velocity increased from 0.9 m/s to 1.9 m/s.

Author Biography

Husam A. Hassan, Department of Studies, Planning & Follow-up, Ministry of Higher Education & Scientific Research,10060 Baghdad, Iraq

Electromechanical Engineering Department, University of Technology, 10066, Baghdad, Iraq

Downloads

Published

2023-03-31

How to Cite

[1]
M. J. Al-Dulaimi, Areej H. Hilal, Husam A. Hassan, and Faik A. Hamad, “Energy and Exergy Investigation of a Solar Air Heater for Different Absorber Plate Configurations”, Int. J. Automot. Mech. Eng., vol. 20, no. 1, pp. 10258–10273, Mar. 2023.

Issue

Section

Articles

Similar Articles

<< < 3 4 5 6 7 8 9 10 11 12 > >> 

You may also start an advanced similarity search for this article.