Impact of Outlet Vent Configurations on Indoor Environmental Quality, Occupant Comfort, and Energy Efficiency: An Optimisation Study

Authors

  • Ghogare Abhijeet Ganesh MAEER's Maharashtra Institute of Technology, Mumbai, Bharat, Maharashtra, 401107, India
  • Shobha Lata Sinha Department of Mechanical Engineering, National Institute of Technology Raipur, 492013, India
  • Vijay Panchore Department of Mechanical Engineering, Maulana Azad National Institute of Technology, Bhopal, 462003, India
  • Tikendra Nath Verma Department of Mechanical Engineering, Maulana Azad National Institute of Technology, Bhopal, 462003, India

DOI:

https://doi.org/10.15282/ijame.22.4.2025.4.0981

Keywords:

PMV, PPD, Energy efficiency, Optimisation, Thermal comfort

Abstract

The rising demand for building energy and the time spent indoors are driving the need for a sustainable balance between building energy demand and occupant comfort. The detailed analysis of fluid flow, radiation heat transfer, heat load on a radiator, and the comfort of indoor occupants is essential for sustainable buildings. This study numerically evaluates the well-validated 3D empty-room model for energy demand in a cold-climate environment to support occupant comfort. Efforts have been made to optimise the factors affecting occupant comfort and the energy demand of the office room to maintain sustainable stability. A well-validated 3-dimensional model simulated airflow, heat transfer, and occupant comfort. The study optimises factors affecting comfort and energy use using multi-objective optimisation (MOO) techniques. Outlet vent location significantly impacts indoor comfort, energy, and fluid flow. Indoor environments can be optimised for both energy and comfort, especially in symmetrical indoor spaces. Floor-level vents improve air circulation but have little impact on energy use in cold climates. In symmetrical fluid domains, symmetrical outlet vent placement achieved the lowest objective function value (0.026), with a heat load of 412.27 W, PMV of 0.24, and PPD of 7.12, whereas floor-level outlet vents showed the highest objective function value (0.575), with PMV of 0.51 and PPD of 12.11, indicating reduced comfort. Overall, optimising ventilation strategies allows for prioritising occupant comfort and energy efficiency based on specific needs.

References

[1] A. Hamburg, Ü. Palmiste, A. Mikola, and T. Kalamees, “Ventilation Strategies for Deep Energy Renovations of High-Rise Apartment Buildings: Energy efficiency and implementation challenges,” Energies, vol. 18, no. 11, p. 2785, 2025.

[2] ASHRAE, 10P Guideline: Interactions Affecting the Achievement of Acceptable Indoor Environments, 2nd Public Review, Atlanta, USA: ASHRAE, 2010.

[3] X. Su, Y. Yuan, Z. Wang, W. Liu, L. Lan, and Z. Lian, “Human thermal comfort in non-uniform thermal environments: A review,” Energy and Built Environment, vol. 5, no. 6, pp. 853–862, 2023.

[4] G. A. Ganesh, S. L. Sinha, T. N. Verma, and S. K. Dewangan, “Investigation of indoor environment quality and factors affecting human comfort: A critical review,” Building and Environment, vol. 204, p. 108146, 2021.

[5] D. Kajjoba, R. Wesonga, J. D. Lwanyaga, “Assessment of thermal comfort and its potential for energy efficiency in low-income tropical buildings: a review,” Sustainable Energy Research, vol. 12, p. 25, 2025.

[6] J. Wang, T. Zhang, S. Wang, and F. Battaglia, “Numerical investigation of single-sided natural ventilation driven by buoyancy and wind through variable window configurations,” Energy and Buildings, vol. 168, pp. 147–164, 2018.

[7] V. Tuninetti, B. Ales, and T. Mora Chandía, “Numerical and experimental analysis of thermal stratification in locally heated residential spaces,” Buildings, vol. 15, no. 14, p. 2417, 2024.

[8] Y. Cheng, J. Niu, Z. Du, and Y. Lei, “Investigation on the thermal comfort and energy efficiency of stratified air distribution systems,” Energy for Sustainable Development, vol. 28, pp. 1–9, 2015.

[9] S. Zhang, J. Jiang, Y. Cheng, C. Huan, and Z. Lin, “Equivalent room air temperature-based cooling load estimation method for stratum ventilation,” in Stratum Ventilation—Advanced Air Distribution for Low-Carbon and Healthy Buildings, S. Zhang, Y. Cheng, and Z. Lin, Eds. Singapore: Springer, 2024.

[10] G. A. Ganesh, S. L. Sinha, and T. N. Verma, “Effect of inlet airflow direction on the indoor environment of a naturally ventilated room using CFD,” International Journal of Engineering and Advanced Technology, vol. 9, no. 3, pp. 580–591, 2020.

[11] A. Longhitano, V. Costanzo, G. Evola, and F. Nocera, “Microclimate investigation in a conference room with thermal stratification: An investigation of different air conditioning systems,” Energies, vol. 17, no. 5, p. 1188, 2023.

[12] G. A. Ganesh, S. L. Sinha, T. N. Verma, and S. K. Dewangan, “Numerical simulation for energy consumption and thermal comfort in a naturally ventilated indoor environment under different orientations of inlet diffuser,” Building and Environment, vol. 217, p. 109071, 2022.

[13] A. A. Sedighi, F. Haghighat, and F. Nasiri, “Strategic ventilation design for reducing airborne infection transmission in a two-story building: A numerical approach,” Building and Environment, vol. 262, p. 111785, 2024.

[14] C. Zhang, Y. Bai, Z. Cao, et al., “Critical factors to formatting and stabilising the vortex flow in the vortex ventilation system,” Building Simulation, vol. 18, pp. 403–421, 2025.

[15] S. Wu, L. Wu, and L. Xiao, “Effects of aspect ratio and inlet wind velocity on thermal characteristics of Trombe wall channel under different ventilation strategies: An indoor experiment,” Experimental Thermal and Fluid Science, vol. 141, p. 110800, 2023.

[16] D. Qiao, S. Wu, N. Zhang, and C. Qin, “Optimising the return vent height for improved performance in stratified air distribution systems,” Buildings, vol. 14, no. 4, p. 1008, 2024.

[17] P. O. Fanger, “Assessment of man's thermal comfort in practice,” Occupational and Environmental Medicine, vol. 30, no. 4, pp. 313–324, 1973.

[18] P. V. Nielsen, “Analysis and design of room air distribution systems,” HVAC&R Research, vol. 13, no. 6, pp. 987–997, 2007.

[19] Y. Balali, A. Chong, A. Busch, and S. O’Keefe, “Energy modelling and control of building heating and cooling systems with data-driven and hybrid models—A review,” Renewable and Sustainable Energy Reviews, vol. 183, p. 113496, 2023.

[20] D. W. Etheridge and M. Sandberg, Building ventilation: theory and measurement, vol. 50. Chichester, UK: John Wiley & Sons, 1996.

[21] Y. Li, L. Li, X. Cui, and P. Shen, “Coupled building simulation and CFD for real-time window and HVAC control in sports space,” Journal of Building Engineering, vol. 97, p. 110731, 2024.

[22] J. A. Myhren and S. Holmberg, “Flow patterns and thermal comfort in a room with a panel, floor, and wall heating,” Energy and Buildings, vol. 40, pp. 524–536, 2008.

[23] T. Long, Y. Li, W. Li, S. Liu, J. Lu, D. Zheng, K. Ye, Z. Qiao, and S. Huang, “Investigation on the cooling performance of a buoyancy driven earth-air heat exchanger system and the impact on indoor thermal environment,” Applied Thermal Engineering, vol. 207, p. 118148, 2022.

[24] S. Mohammadreza, P. A. Mirzaei, and N. Mohammad, “Improvement of k-epsilon turbulence model for CFD simulation of atmospheric boundary layer around a high-rise building using stochastic optimisation and Monte Carlo sampling technique,” Journal of Wind Engineering and Industrial Aerodynamics, vol. 171, pp. 366–379, 2017.

[25] Z. Zhai, Z. Zhang, W. Zhang, and Chen, “Evaluation of various turbulence models in predicting airflow and turbulence in enclosed environments by CFD: Part-1: summary of prevalent turbulence models,” HVAC&R Research, vol. 13, no. 6, pp. 1–21, 2007.

[26] C. Buratti, D. Palladino, and E. Moretti, “Prediction of Indoor Conditions and Thermal Comfort Using CFD Simulations: A Case Study Based on Experimental Data,” Energy Procedia, vol. 126, pp. 115–122, 2017.

[27] K. Ravindra, N. Agarwal, and S. Mor, “Assessment of thermal comfort parameters in various car models and mitigation strategies for extreme heat-health risks in the tropical climate,” Journal of Environmental Management, vol. 267, p. 110655, 2020.

[28] H. Wang, H. Wang, F. Gao, P. Zhou, and Z. J. Zhai, “Literature review on pressure–velocity decoupling algorithms applied to built-environment CFD simulation,” Building and Environment, vol. 143, pp. 671–678, 2018.

[29] L. Huang and Z. Zhai, “Critical review and quantitative evaluation of indoor thermal comfort indices and models incorporating solar radiation effects,” Energy and Buildings, vol. 224, p. 110204, 2020.

[30] B. W. Olesen, E. Mortensen, J. Thorshauge, and B. Berg-Munch, “Thermal comfort in a room heated by a different method,” ASHRAE Transactions, vol. 86, Tech. Paper no. 2556, 1980.

[31] K. Horikiri, Y. Yao, and J. Yao, “Numerical optimisation of thermal comfort improvement for an indoor environment with occupants and furniture,” Energy and Buildings, vol. 88, pp. 303–315, 2015.

[32] G. A. Ganesh, S. L. Sinha, and T. N. Verma, “Numerical simulation for optimisation of the indoor environment of an occupied office building using double-panel and ventilation radiator,” Journal of Building Engineering, vol. 29, p. 101139, 2020.

[33] P. Niemann and G. Schmitz, “Impacts of occupancy on energy demand and thermal comfort for a large-sized administration building,” Building and Environment, vol. 182, p. 107027, 2020.

[34] T. Cheung, S. Schiavon, T. Parkinson, P. Li, and G. Brager, “Analysis of the accuracy on PMV–PPD model using the ASHRAE Global Thermal Comfort Database II,” Building and Environment, vol. 153, pp. 205–217, 2019.

[35] D. Khovalyg, O. B. Kazanci, H. Halvorsen, I. Gundlach, W. P. Bahnfleth, J. Toftum, and B. W. Olesen, “A critical review of standards for indoor thermal environment and air quality,” Energy and Buildings, vol. 225, p. 109819, 2020.

[36] P. O. Fanger and J. Toftum, “Extension of the PMV model to non-air-conditioned buildings in warm climates,” Energy and Buildings, vol. 34, no. 6, pp. 533–536, 2002.

[37] E. W. Shaw, “Thermal comfort: Analysis and applications in environmental engineering, by P. O. Fanger,” Royal Society of Health Journal, vol. 92, no. 3, p. 164, 1972.

[38] ISO 15265, Ergonomics of the thermal environment – Strategy of evaluation of the risk for the prevention of constraints or discomfort under thermal working conditions, Geneva: International Standardisation Organisation, 2004.

Downloads

Published

2025-11-16

Issue

Section

Articles

How to Cite

[1]
G. A. Ganesh, S. L. Sinha, V. Panchore, and T. N. Verma, “Impact of Outlet Vent Configurations on Indoor Environmental Quality, Occupant Comfort, and Energy Efficiency: An Optimisation Study”, Int. J. Automot. Mech. Eng., vol. 22, no. 4, pp. 12887–12902, Nov. 2025, doi: 10.15282/ijame.22.4.2025.4.0981.